Accurate waste tank use air pressure liquid oil hydraulic resistive mv output OEM pressure sensor MPM280

Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280 Features:      1. Pressure range: 0~20kPa...100MPa      2. Isolated construction      3. 19mm diameter      4. OEM&nbs

Featured Products

Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280
 

Features:

      1. Pressure range: 0~20kPa...100MPa
      2. Isolated construction
      3. 19mm diameter
      4. OEM
      5. Cost-effective
      6. Ti diaphragm optional
 
Electric Performance
      1. Power supply: ≤2.0mA DC; ≤10V DC
      2. Electric connection: Kovar pin or 100mm silicon rubber flexible wires
      3. Common mode voltage output: 50% of input (typ.)
      4. Input impedance: 3kΩ~8kΩ
      5. Output impedance: 3.5kΩ~6kΩ
      6. Response (10%~90%): <1ms
      7. Insulation resistor: 100MΩ, 100VDC
      8. Overpressure: 1.5 times FS
 
Basic Condition
      1. Media temperature: (25±1)ºC
      2. Environment temperature: (25±1)ºC
      3. Shock: 0.1g (1m/s/s) Max
      4. Humidity: (50%±10%)RH
      5. Local air pressure:(86~106)kPa
      6. Power supply: (1.5±0.0015)mADC
 
Basic Specifications:
Item*Min.Typ.Max.Units
Linearity ±0.15±0.25%FS,BFSL
Repeatability ±0.05±0.075%FS
Hysteresis ±0.05±0.075%FS
Zero output  ±2mVDC
FS output**70  mVDC
Zero thermal error ±0.75±1.0%FS, @25ºC
FS thermal error ±0.75±1.0%FS, @25ºC
Compensated temp. range0~50ºC
Working temp. range-40~125ºC
Storage temp. range-40~125ºC
Stability ±0.2±0.3%FS/year
*testing at basic condition,G: Gauge; A: Absolute; S: Sealed gauge
** 0AG, FS output ≥60mV
  0BG, FS output ≥45mV
  02A, 03A, 02GY, 03GY, FS output ≥50mV
  07A, 08A, 07GY, 08GY, FS output ≥60mV
 

Outline Construction:
(Unit:mm)
Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280

Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280

Electric Connection:
Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280

 
Order Information:

MPM280(TH/TS/HHTi)*

Piezoresistive OEM Pressure Sensor

 

 

Range code

Pressure range

Ref.

Range code

Pressure range

Ref.

0B

0kPa~20kPa

G

12

0MPa~2MPa

G.A

0A

0kPa~35kPa

G.A

13

0MPa~3.5MPa

G.S.A

02

0kPa~70kPa

G.A

14

0MPa~7MPa

S.A

03

0kPa~100kPa

G.A

15

0MPa~10MPa

S.A

07

0kPa~200kPa

G.A

17

0MPa~20MPa

S.A

08

0kPa~350kPa

G.A

18

0MPa~35MPa

S.A

09

0kPa~700kPa

G.A

19

0MPa~70MPa

S.A

10

0kPa~1000kPa

G.A

20

0MPa~100MPa

S.A

 

 

Code

Pressure type

G

Gauge

A

Absolute

S

Sealed gauge

 

 

Code

Pressure connection

Installation

0 or null

O-ring

H1

M24×1 male

(assembled, P≤2MPa)

C1~C11 are available for pressure connections for both assembled and welded type

H2

M27×2 male

(assembled, P≤70MPa)

H3

M24×1 male

(welded, P≤2MPa)

H4

M27×2 male

(welded, P≤35MPa)

C1

M20×1.5 male,

face type seal

Pressure connection options for assembled or welded type

C2

G1/4 male

C3

G1/2 male

C4

G1/4 female

C5

M20X1.5male

waterline seal

C6

1/4NPT male

C7

1/4NPT female

C8

1/2NPT male

C9

1/2NPTfemale

C10

R1/4 male

C11

R1/2 male

PC1

Flush diaphragm

M20×1.5 male,

Top: M24×1 female

PC2

Flush diaphragm

R1/2 male,

PC3

Flush diaphragm

G1/2 male,

PD1

DN25 clamp

 

 

Code

Compensation

L

Laser trimming

M

Outer compensated resistor

(providing resistor value)

 

 

 

 

 

 

 

Code

Electric connection

1

Kovar pin(default)

2**

100mm silicon rubber flexible wires

 

 

Code

Special measurement

Y

Gauge sensor to measure vacuum(0kPa~-100kPa)

 

 

MPM280 09 G 0 L 1 Y The whole spec


Certificates We Have
Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280



Company Overview
Accurate Wasted Tank Use Barometric Liquids Oil Fluids Piezoresistive mv Output OEM Pressure Sensor MPM280



FAQ:
1. Q: Are you manufacturer or trading company?
    A: We are 48-year professional manufacturer of Pressure/ Level/ Temperature/Flow transmitters with 4~20mA, Hart, Rs485 & Modbus protocols, pressure sensors with SDI, I2C, 4~20mA, 0.5~4.5V and etc, and wireless IOT measurement transmitters. We provide high quality products with high competitive factory price.
 
2. Q: What's your quality control system?
    A: As an ISO9001:2008 certificated manufacturer, we have strict quality control system, and each product is done fatigue testing, calibration, temperature compensation before shipment. High quality is guaranteed.
 
3Q: Is there MOQ with your product?
    A: We have no MOQ limits, 1pc for testing is acceptable.
 
4Q: Do you provide customized products?
    A: Yes, we can print your logo on our products; OEM, ODM & customization are welcomed.
 
5. Q: What is the warranty of your products? And after-sales service?
    A: Our warranty time is 12 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.
 
6. Q: What is lead time of your product?
    A: We are factory, our lead time is always within 10~15 working days for products without customization, but lead time will vary based on different products. You can check detail lead time with our sales.

7. Q: What international certificates do you have for your products?
    A: we have CE, RoHS, UL, ATEX as well as ship-use DNV etc.

 

Contact us