Non Contact Ultrasonic Module Distance Measuring Transducer Sensor 

Technical parameters:
 
 
                         

Technical parameters:
| DUltrasonic sensor | |
| Technical data | |
| General Specifications | |
| Sensing distance | 180…2500mm | 
| Adjustment range | 180…2500mm | 
| Unusable area | 0…18mm | 
| Standard target plate | 100mm×100mm | 
| Transducer frequency About | 100 kHz | 
| Response delay About | 125ms | 
| Indicators/Operating means | |
| LED yellow | solid: object in evaluation range flash: program function | 
| LED red | flashing: program function | 
| Electrical specifications | |
| Operating voltage UB | 10…30VDC ripple10%ss | 
| No-load supply current | ≤20mA | 
| Output | |
| Output type | 1 analogue output 4…20mA | 
| Resolution | |
| Deviation of the characteristic curve | ±1% of full-scale value | 
| Repeat accuracy | ±0.1% of full-scale value | 
| Load impedance | >1k Ohm | 
| Maximum switching current | 200 mA | 
| Temperature influence | ±1.5% of full-scale value | 
| Ambient conditions | |
| Ambient temperature | -25…70ºC | 
| Storage temperature | -40…85ºC | 
| Mechanical specifications | |
| Protection grade | IP67 | 
| Connection | Connector M12,4-PIN | 
| Material | |
| Housing | Brass nickel-plated | 
| Transducer | epoxy resin/hollow glass sphere mixture; Polyurethane foam | 
| Weight | 160g | 
| Compliance with standards and Directives | |
| Standard conformity | EN 60947-5-2:2007 | 
Image:

 



Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with -UB, A2 with +UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
Evaluation limits may only be specified within the first 5 minutes after
Power on. To modify the evaluation limits later,
the user may specify the desired values only after a new Power On.
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + UB
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with - UB
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
LED Displays
| Displays in dependence on operating mode | Red LED | Yellow LED | 
| TEACH-IN evaluation limit Object detected No object detected Object uncertain (TEACH-IN invalid) | off flashes on | flashes off off | 
| Normal mode (evaluation range) | off | on | 
| Fault | on | previous state |