Technical parameters:
Term | Technique Data | Picture | |
Name | 100KHz Antiseptic transducer | ![]() | |
Model | PH-100-02Ph | ||
Frequency | 100KHz±5% | ||
Measure distance | 0.15~2m | ||
Minimum Impedance | 700Ω±20% | ||
Capacity | 2100pF±20% @1KHz | ||
Sensitivity | No-load drive voltage:300Vpp, Distance 0.3m, Echo amplitude 40mV | ||
working voltage | peak voltage<800Vpp | ||
Working Temperature | -40~+80ºC | ||
Pressure | ≤3Kg or 0.3MPa | ||
Housing material | PVDF | ||
Application | Ultrasonic level meter, monitoring, anti-collision, safety | ||
Mounting dimension | See the structure diagram | ||
Protection grade | IP68 | ||
weight | 300g±5% | ||
wiring instructions | integral:Interface (3PIN,2.54mm):Red positive, white negative, black shielding line; Interface (3PIN,2.0mm):White and black are temperature sensor lines MF58); | ||
Admittance curve diagram | product structure diagram | ||
![]() | ![]() |
Block diagram of ultrasonic Distance transducer :
Schematic Diagram of Temperature Sensor (model: MF58_502F3470):
Integrated type Cable instruction:
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding
2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)
Red and black are temperature sensor wiring
Split type: standard 10m cable, with each additional 50m of cable, the signal attenuation is 6dB
Three-core wiring instructions:
Red: Transducer +
Blue: temperature sensor +
Black: Public-
Four-core wiring instructions:
Red: Transducer +
Yellow: Transducer-
Blue, black: temperature sensor